Type: | Water Treatment Equipment |
---|---|
Method: | Combined Treatment |
Usage: | Industrial, Home, Agriculture, Hospital |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Integrated Membrane Bioreactor(MBR) Wastewater Treatment Module
& Flexible Flat Sheet Membranes
Introduction:
We are a leading flexible flat sheet membrane manufacturer independently developing the component with first fully automatic production line from formula to film scraping machine to forming and assembling and we mainly specialized in flat-sheet membrane rolls with PVDF material, which are suitable for MBR and immersion ultrafiltration. PVDF's non-viscosity (low surface energy) gives it better pollution resistance. We adopt permanent hydrophilic modification, which can optimize the pollution resistance and flux. CPVC molecule has a lot of negative covalent bond chlorine in it, which makes the surface of the material more negatively charged, while most of the impurities in the wastewater are electronegative, so the fouling resistance property is also very good.
Our LR Series flexible flat sheet membrane module not only retains the advantages of conventional flat membrane like high strength, easy maintenance, no backwash, high flux and low transmembrane pressure difference, but also include the advantages of hollow fiber membrane like high filling density, small floor area and lower gas-water ratio. At the same time, our products have the advantages of extreme low replacement cost of single membrane, high welding strength and backwash available. Our MBR membrane wastewater treatment system can replace traditional biological wastewater treatment technology on a large scale and wide application ranges.
Membranes Stack Unit:
Our LR flexible flat sheet membrane stack consists of rectangle membrane, sealing ring, spacing strip, central water collecting pipe and two ends baffles. Membranes and sealing rings are putted on the center pipe on by one and then pressed and sealed by the baffles on both sides. After filtered by the membranes the wastewater first enters the support passage and then will be collected to the central water collecting pope for export with the activated sludge keeping out of the diaphragm. The pore size of these membranes is 0.03-0.1μm while the material is most commonly used PVDF.
Basical Parameters of LR Membrane Stack:
Model | LR4 | LR8 | LR9 |
Membrane Size(mm) | 250x250 | 250x250 | 250x250 |
Membrane Spacing(mm) | 4 | 8 | 8 |
Average Thickness(mm) | 0.7 | 0.7 | 0.7 |
Membrane Count(pcs) | 182 | 114 | 208 |
Stack Area Size(m2) | 20 | 12.5 | 23 |
Stack Outline Dimension(mm) | 528x520x252 | 528x520x252 | 528x920x252 |
Membrane Material | PVDF | PVDF | PVDF |
Discharging Pipe Count | 2 | 2 | 2 |
Flow Rate(L/H) | 200-600 | 125-375 | 230-690 |
Working Pressure Differential(m) | 0.2-6 | 0.2-4 | 0.2-4 |
Application | Immersed Ultrafiltration | MBR | MBR |
pH | 2-12 | ||
Discharging Water Turbidity | ≤1NTU |
Flat Sheet Membranes Assembly Module:
The basic structure of LR flat sheet membrane assembly module mainly contains three parts as shown in the following figure: aeration part, membrane box part and water collecting pipe part.
Features:
Welding strength x5 times stronger due to optimized memebrane forming technique
Single membrane can wobble under aeration just like hollow membrane
Single membrane and single stack can be replaced easily
Good hydrophilicity and fouling resistant
High adsorption to substrate material and backwash applicable
High loading density, high water-air ratio, low operating cost
Low transmembrane pressure
General frame adopting gravity-buoyancy balance design, high stability, long service life
Membranes stack unit can be demounted and maintained online
Reasonable module size, flexible installation design
Super-high cost effective
Comparison between LR flexible flat sheet membrane and hollow fiber membrane:
Item | LR Flexible Flat Film | Hollow Fiber Film | Conventional Flat Film |
Flux/LMH | 10-30 | 10-20 | 10-30 |
Loading Density | Equivalent | Low | |
Air Quantity per Water Treatment Unit | Equivalent | Higher | |
Backwash Required or Not | No(Available if required) | Yes | Not Applicable |
Wobble or Not | Yes | Yes | Not |
Membrane Silk Can Broke or Not | Not | Yes | Not |
Service Life | Long | Short | Long |
Pre-filtration Requirement(Gird Diameter) | 2mm | 1mm | 2mm |
Offline Cleaning Needed or Not | Not Usually | Yes | Not Usually |
Tranmembrane Pressure Differential(m) | 0.05-0.3 | 0.1-0.6 | 0.06-0.3 |
Investment Cost/Operating Cost | Low/Low | Low/High | High/High |
Parameters for Standard LR Series Membranes Assembly Module:
Model |
Membrane Stack Layers Count |
Membrane Stack Columns Count |
Membrane Stack Count |
Total Membrane Area | Outline Size (LxWxH) |
Domestic Sewage Treatment Capacity |
Industrial Sewage Treatment Capacity |
m2 | mm | t/d | t/d | ||||
LR8-1-2 | 1 | 2 | 2 | 25.0 | 700x700x1230 | 10 | 7.5 |
LR8-1-4 | 1 | 4 | 4 | 50.0 | 1250x700x1230 | 20 | 15.0 |
LR8-2-3 | 2 | 3 | 6 | 75.0 | 1000x700x1770 | 30 | 22.5 |
LR8-2-4 | 2 | 4 | 8 | 100.0 | 1250x700x1770 | 40 | 30.0 |
LR8-2-5 | 2 | 5 | 10 | 125.0 | 1500x700x1770 | 50 | 37.5 |
LR8-2-6 | 2 | 6 | 12 | 150.0 | 1750x700x1770 | 60 | 45.0 |
LR8-3-5 | 3 | 5 | 15 | 187.5 | 1500x700x2440 | 75 | 56.2 |
LR8-3-6 | 3 | 6 | 18 | 225.0 | 1750x700x2440 | 90 | 67.5 |
LR8-3-8 | 3 | 8 | 24 | 300.0 | 2250x700x2440 | 120 | 90.0 |
Model |
Membrane Stack Layers Count |
Membrane Stack Columns Count |
Membrane Stack Count |
Total Membrane Area | Outline Size (LxWxH) |
Domestic Sewage Treatment Capacity |
Industrial Sewage Treatment Capacity |
m2 | mm | t/d | t/d | ||||
LR9-1-2 | 1 | 2 | 2 | 46.0 | 700x1100x1230 | 18.4 | 13.8 |
LR9-1-4 | 1 | 4 | 4 | 92.0 | 1250x1100x1230 | 36.8 | 27.6 |
LR9-2-3 | 2 | 3 | 6 | 138.0 | 1000x1100x1770 | 55.2 | 41.4 |
LR9-2-4 | 2 | 4 | 8 | 184.0 | 1250x1100x1770 | 73.6 | 55.2 |
LR9-2-5 | 2 | 5 | 10 | 230.0 | 1500x1100x1770 | 92.0 | 69.0 |
LR9-2-6 | 2 | 6 | 12 | 276.0 | 1750x1100x1770 | 110.4 | 82.8 |
LR9-3-5 | 3 | 5 | 15 | 345.0 | 1500x1100x2440 | 138.0 | 103.5 |
LR9-3-6 | 3 | 6 | 18 | 414.0 | 1750x1100x2440 | 165.6 | 124.2 |
LR9-3-8 | 3 | 8 | 24 | 552.0 | 2250x1100x2440 | 220.8 | 165.6 |
LR9-3-12 | 3 | 12 | 36 | 828.0 | 3300x1100x2440 | 331.0 | 248.0 |
LR9-4-12 | 4 | 12 | 48 | 1104.0 | 3300x1100x3000 | 441.6 | 331.2 |
Notes: The filtration capacity of membranes module is obtained according to the membrane area multiply by flux. It's suggested that the flux of municipal sewage seen as 400L/dayxsquare meter, please calibrate the flux for industrial sewage. The water yield in the table is calculated according to the effective working time of 20h per day while the operating mode is running for 8 minutes and stopping for 2 minutes, or running for 9 minutes and stopping for 1 minute.
Typical Discharging Effluent Quality:
TSS < 2mg/L
Turbidity < 0.1NTU(Ultrafiltration), 1NTU(MBR)
COD decline, COD would be controlled under 50mg/L while the biochemical system is well treated
NH4-N decline, NH4-N would be controlled under 1mg/L while the biochemical system is well treated
Pipeline Connection Diagram for Membranes Assembly Module:
As shown in the figure, the membranes module is connected to three main pipelines: output water pipeline, backwash pipeline and aeration pipeline. The water collecting port is connected with the water output pipeline and the backwash pipeline through a three-way connection. The backwash pipeline is connected to the high-level cleaning water tank which can backwash the membranes with cleaning water or solution. The water tank is 0.5-1 meters higher than the membrane assembly module, so the solution in the tank can be injected into the diaphragm by gravity or backwash pump. The aeration pipeline is connected to the air inlet of the membranes module while the other end of the membrane module is a vent with a vent valve which mainly play the role of flushing the aerator.
Applications:
Underground water -- Ultrafiltration
Surface water -- Chemically enhanced ultrafiltration or ultrafilter directly
Lightly polluted water/Tertiary treatment -- Chemically enhanced ultrafiltration/MBR
Sewage -- MBR
Domestic sewage integrated equipment
Industrial ultrafiltration equipment
Secondary sedimentation tank
Printing and dyeing wastewater tank modifying and upgrading
Pharmaceutical wastewater tank modifying and upgrading
Workshop and Delivery: