Mbr Sewage Treatment Plant/Pulp and Paper Industry Wastewater Treatment Equipment

Product Details
Type: Water Treatment Equipment
Method: Combined Treatment
Usage: Industrial, Home, Agriculture, Hospital
Manufacturer/Factory, Trading Company
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 14064
  • Mbr Sewage Treatment Plant/Pulp and Paper Industry Wastewater Treatment Equipment
  • Mbr Sewage Treatment Plant/Pulp and Paper Industry Wastewater Treatment Equipment
  • Mbr Sewage Treatment Plant/Pulp and Paper Industry Wastewater Treatment Equipment
  • Mbr Sewage Treatment Plant/Pulp and Paper Industry Wastewater Treatment Equipment
  • Mbr Sewage Treatment Plant/Pulp and Paper Industry Wastewater Treatment Equipment
  • Mbr Sewage Treatment Plant/Pulp and Paper Industry Wastewater Treatment Equipment
Find Similar Products

Basic Info.

Model NO.
LR8
Membrane Type
Flexible Flat Sheet
Membrane Material
Pdfv
Membrane Size
250X250mm
Membrane Pore Size
0.03-0.1μm
Applicable to
Mbr & Immersed Ultrafiltration
Application
Domestic, Municipal, Industrial
Membrane Average Thickness
0.7mm
Outlet Water Turbidity
≤1ntu
Ultrafiltration Outlet Turbidity
≤0.1ntu
Lmh
10-30
Transmembrane Pressure Differential
0.05-0.3
Membrane Stack Size
528X920X252mm, 528X520X252mm
Module Size
Customized Accordingly
Transport Package
Non-Fumigation Wooden Box or Wooden Pallet
Origin
China
HS Code
8421999090
Production Capacity
2000 Sets Yearly

Product Description

Integrated Membrane Bioreactor(MBR) Wastewater Treatment Module

Introduction:
We are a leading flexible flat sheet membrane manufacturer independently developing the component with first fully automatic production line from formula to film scraping machine to forming and assembling and we mainly specialized in flat-sheet membrane rolls with PVDF material, which are suitable for MBR and immersion ultrafiltration. PVDF's non-viscosity (low surface energy) gives it better pollution resistance. We adopt permanent hydrophilic modification, which can optimize the pollution resistance and flux. CPVC molecule has a lot of negative covalent bond chlorine in it, which makes the surface of the material more negatively charged, while most of the impurities in the wastewater are electronegative, so the fouling resistance property is also very good.

Our LR Series flexible flat sheet membrane module not only retains  the advantages of conventional flat membrane like high strength, easy maintenance, no backwash, high flux and low transmembrane pressure difference, but also include the advantages of hollow fiber membrane like high filling density, small floor area and lower gas-water ratio. At the same time, our products have the advantages of  extreme low replacement cost of single membrane, high welding strength and backwash available. Our MBR membrane wastewater treatment system can replace traditional biological wastewater treatment technology on a large scale and wide application ranges.

Membranes Stack Unit:
Mbr Sewage Treatment Plant/Pulp and Paper Industry Wastewater Treatment Equipment

Our LR flexible flat sheet membrane stack consists of rectangle membrane, sealing ring, spacing strip, central water collecting pipe and two ends baffles. Membranes and sealing rings are putted on the center pipe on by one and then pressed and sealed by the baffles on both sides. After filtered by the membranes the wastewater first enters the support passage and then will be collected to the central water collecting pope for export with the activated sludge keeping out of the diaphragm. The pore size of these membranes is 0.03-0.1μm while the material is most commonly used PVDF.

Basical Parameters of LR Membrane Stack:

Model LR4 LR8 LR9
Membrane Size(mm) 250x250 250x250 250x250
Membrane Spacing(mm) 4 8 8
Average Thickness(mm) 0.7 0.7 0.7
Membrane Count(pcs) 182 114 208
Stack Area Size(m2) 20 12.5 23
Stack Outline Dimension(mm) 528x520x252 528x520x252 528x920x252
Membrane Material PVDF PVDF PVDF
Discharging Pipe Count 2 2 2
Flow Rate(L/H) 200-600 125-375 230-690
Working Pressure Differential(m) 0.2-6 0.2-4 0.2-4
Application Immersed Ultrafiltration MBR MBR
pH 2-12
Discharging Water Turbidity ≤1NTU

Flat Sheet Membranes Assembly Module:
The basic structure of LR flat sheet membrane assembly module mainly contains three parts as shown in the following figure: aeration part, membrane box part and water collecting pipe part.
Mbr Sewage Treatment Plant/Pulp and Paper Industry Wastewater Treatment Equipment

Features:
Welding strength x5 times stronger due to optimized memebrane forming technique
Single membrane can wobble under aeration just like hollow membrane
Single membrane and single stack can be replaced easily
Good hydrophilicity and fouling resistant
High adsorption to substrate material and backwash applicable
High loading density, high water-air ratio, low operating cost
Low transmembrane pressure
General frame adopting gravity-buoyancy balance design, high stability, long service life
Membranes stack unit can be demounted and maintained online
Reasonable module size, flexible installation design
Super-high cost effective

Mbr Sewage Treatment Plant/Pulp and Paper Industry Wastewater Treatment Equipment

Comparison between LR flexible flat sheet membrane and hollow fiber membrane:

Item LR Flexible Flat Film  Hollow Fiber Film Conventional Flat Film
Flux/LMH 10-30 10-20 10-30
Loading Density Equivalent Low
Air Quantity per Water Treatment Unit Equivalent Higher
Backwash Required or Not No(Available if required) Yes Not Applicable
Wobble or Not Yes Yes Not
Membrane Silk Can Broke or Not Not Yes Not
Service Life Long Short Long
Pre-filtration Requirement(Gird Diameter) 2mm 1mm 2mm
Offline Cleaning Needed or Not Not Usually Yes Not Usually
Tranmembrane Pressure Differential(m) 0.05-0.3 0.1-0.6 0.06-0.3
Investment Cost/Operating Cost Low/Low Low/High High/High

Parameters for Standard LR Series Membranes Assembly Module:

Model
 
Membrane Stack Layers
Count

 
Membrane Stack Columns
Count

 
Membrane Stack Count
 
Total Membrane Area Outline Size
(LxWxH)
Domestic
Sewage Treatment Capacity
Industrial Sewage Treatment Capacity
 
m2 mm t/d t/d
LR8-1-2 1 2 2 25.0 700x700x1230 10 7.5
LR8-1-4 1 4 4 50.0 1250x700x1230 20 15.0
LR8-2-3 2 3 6 75.0 1000x700x1770 30 22.5
LR8-2-4 2 4 8 100.0 1250x700x1770 40 30.0
LR8-2-5 2 5 10 125.0 1500x700x1770 50 37.5
LR8-2-6 2 6 12 150.0 1750x700x1770 60 45.0
LR8-3-5 3 5 15 187.5 1500x700x2440 75 56.2
LR8-3-6 3 6 18 225.0 1750x700x2440 90 67.5
LR8-3-8 3 8 24 300.0 2250x700x2440 120 90.0
Model
 
Membrane Stack Layers
Count

 
Membrane Stack Columns
Count

 
Membrane Stack Count
 
Total Membrane Area Outline Size
(LxWxH)
Domestic
Sewage Treatment Capacity
Industrial Sewage Treatment Capacity
 
m2 mm t/d t/d
LR9-1-2 1 2 2 46.0 700x1100x1230 18.4 13.8
LR9-1-4 1 4 4 92.0 1250x1100x1230 36.8 27.6
LR9-2-3 2 3 6 138.0 1000x1100x1770 55.2 41.4
LR9-2-4 2 4 8 184.0 1250x1100x1770 73.6 55.2
LR9-2-5 2 5 10 230.0 1500x1100x1770 92.0 69.0
LR9-2-6 2 6 12 276.0 1750x1100x1770 110.4 82.8
LR9-3-5 3 5 15 345.0 1500x1100x2440 138.0 103.5
LR9-3-6 3 6 18 414.0 1750x1100x2440 165.6 124.2
LR9-3-8 3 8 24 552.0 2250x1100x2440 220.8 165.6
LR9-3-12 3 12 36 828.0 3300x1100x2440 331.0 248.0
LR9-4-12 4 12 48 1104.0 3300x1100x3000 441.6 331.2

Notes: The filtration capacity of membranes module is obtained according to the membrane area multiply by flux. It's suggested that the flux of municipal sewage seen as 400L/dayxsquare meter, please calibrate the flux for industrial sewage. The water yield in the table is calculated according to the effective working time of 20h per day while the operating mode is running for 8 minutes and stopping for 2 minutes, or running for 9 minutes and stopping for 1 minute.

Typical Discharging Effluent Quality:
TSS < 2mg/L
Turbidity < 0.1NTU(Ultrafiltration), 1NTU(MBR)
COD decline, COD would be controlled under 50mg/L while the biochemical system is well treated
NH4-N decline, NH4-N would be controlled under 1mg/L while the biochemical system is well treated

Pipeline Connection Diagram for Membranes Assembly Module:

Mbr Sewage Treatment Plant/Pulp and Paper Industry Wastewater Treatment Equipment
As shown in the figure, the membranes module is connected to three main pipelines: output water pipeline, backwash pipeline and aeration pipeline. The water collecting port is connected with the water output pipeline and the backwash pipeline through a three-way connection. The backwash pipeline is connected to the high-level cleaning water tank which can backwash the membranes with cleaning water or solution. The water tank is 0.5-1 meters higher than the membrane assembly module, so the solution in the tank can be injected into the diaphragm by gravity or backwash pump. The aeration pipeline is connected to the air inlet of the membranes module while the other end of the membrane module is a vent with a vent valve which mainly play the role of flushing the aerator.

Applications:
Underground water -- Ultrafiltration
Surface water -- Chemically enhanced ultrafiltration or ultrafilter directly
Lightly polluted water/Tertiary treatment -- Chemically enhanced ultrafiltration/MBR
Sewage -- MBR
Domestic sewage integrated equipment
Industrial ultrafiltration equipment
Secondary sedimentation tank
Printing and dyeing wastewater tank modifying and upgrading
Pharmaceutical wastewater tank modifying and upgrading

Mbr Sewage Treatment Plant/Pulp and Paper Industry Wastewater Treatment Equipment

Workshop and Delivery:

Mbr Sewage Treatment Plant/Pulp and Paper Industry Wastewater Treatment Equipment
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier